4.6 Limiting Torque

4-35

4

Ope

rat

ion

(3) Changes in Output Torque during External Torque Limiting

The following diagrams show the change in output torque when the internal torque limit is set to 800%.

In this example, the servomotor rotation direction is Pn000.0 = 0 (Sets CCW as forward direction).

4.6.3 Checking Output Torque Limiting during Operation

The following signal can be output to indicate that the servomotor output torque is being limited.

Note: Use parameter Pn50F.0 to allocate the /CLT signal for use. For details, refer to 3.3.2 Output Signal Allocations.

/P-CL

OFF

ON

/N-CL

OFF

ON

Pn402

Pn403

0

Torque

Speed

Pn403

0

Pn404

Pn402

Torque

Speed

0

Pn403

Pn405

Pn402

Torque

Speed

0

Pn403

Pn405

Pn404

Pn402

Torque

Speed

Type

Signal Name

Connector

Pin Number

Setting

Meaning

Output

/CLT

Must be allocated

ON (closed)

Servomotor output torque is being lim-
ited.

OFF (open)

Servomotor output torque is not being
limited.