8 Fully-closed Loop Control

8.1.6 Precautions When Using an External Incremental Encoder by Magnescale

8-10

When Using an External Encoder with Multiple Zero Points and Passing 1st

Zero Point in

Reverse Direction and Returning after Power ON

When using an external encoder with multiple zero points, the same logic as that explained earlier for an

encoder with only one zero point applies to each zero point.
See When Passing 1st Zero Point in Reverse Direction and Returning after Power ON.

To output the phase-C pulse when a detection point is passed in reverse, set the following parameter to 1.

Note: A SERVOPACK with software version 0023 or later supports this parameter.

Parameter

Meaning

When Enabled

Classification

Pn081

n.

0

[Factory Setting]

Outputs phase-C pulse only in forward direction.

After restart

Setup

n.

1

Outputs phase-C pulse in forward and reverse
direction.

Scale count-up direction

Power ON

Time

Phase-C pulse output

Zero point 1

Zero point 3

Zero point 2

Zero point 2

Zero point 2

Phase-C pulse is not output when passing
a zero point in reverse direction.

Zero point 3

Rotation