7 Monitor Displays (Un

)

7-2

7.1 List of Monitor Displays

The monitor displays can be used for monitoring the I/O signal status, and SERVOPACK internal status.

Refer to the following table.

∗1. For details, refer to 7.3 Monitoring Input Signals.

∗2. For details, refer to 7.4 Monitoring Output Signals.

∗3. For details, refer to 4.4.3 Electronic Gear.

∗4. For details, refer to 8.3.3 Setting Encoder Output Pulses (PAO, PBO, and PCO).

∗5. The monitor Un022 can be used only with SGDV-

B SERVOPACKs. For details, refer to 2 Installation

of

Σ

-V Series USER’S MANUAL, Setup, Rotational Motor (No.: SIEP S800000 43).

Parameter

No.

Description

Unit

Un000

Motor rotating speed

min

-1

Un001

Speed reference

min

-1

Un002

Internal torque reference (in percentage to the rated torque)

%

Un003

Rotational angle 1 (encoder pulses from the phase-C origin:
decimal display)

encoder pulse

∗3

Un004

Rotational angle 2 (from polarity origin (electric angle))

deg

Un005

*1

Input signal monitor

Un006

*2

Output signal monitor

Un007

Input reference pulse speed (valid only in position control)

min

-1

Un008

Position error amount (valid only in position control)

reference unit

Un009

Accumulated load ratio (in percentage to the rated torque:
effective torque in cycle of 10 seconds)

%

Un00A

Regenerative load ratio (as a percentage of the processable
regenerative power: regenerative power consumption in cycle
of 10 seconds)

%

Un00B

Power consumed by DB resistance
(in percentage to the processable power at DB activation: dis-
played in cycle of 10 seconds)

%

Un00C

Input reference pulse counter

reference unit

Un00D

Feedback pulse counter

encoder pulse

*3

Un00E

Fully-closed feedback pulse counter

external encoder resolution

*4

Un012

Total operation time

100 ms

Un013

Feedback pulse counter

reference unit

Un014

Effective gain monitor (gain settings 1 = 1, gain settings 2 = 2)

Un015

Safety I/O signal monitor

Un020

Motor rated speed

min

-1

Un021

Motor maximum speed

min

-1

Un022

*5

Installation environment monitor
(Operation conditions in various environments can be moni-
tored.)

%

Un030

The current backlash compensation value

0.1 reference unit

Un031

Backlash compensation setting limit value

0.1 reference unit