3 servopack ratings and specifications, 1 ratings, 1) sgdv with single-phase, 100-v rating – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - MECHATROLINK-II Communications Reference User Manual

Page 23: 2) sgdv with single-phase, 200-v rating, 3) sgdv with three-phase, 200-v rating

Advertising
background image

1.3 SERVOPACK Ratings and Specifications

1-3

1

Outline

1.3 SERVOPACK Ratings and Specifications

This section describes the ratings and specifications of SERVOPACKs.

1.3.1 Ratings

Ratings of SERVOPACKs are as shown below.

(1) SGDV with Single-phase, 100-V Rating

∗ Refer to 3.7 Connecting Regenerative Resistors for details.

(2) SGDV with Single-phase, 200-V Rating

∗1. The official model number is SGDV-120A11A008000.

∗2. Refer to 3.7 Connecting Regenerative Resistors for details.

(3) SGDV with Three-phase, 200-V Rating

∗ Refer to 3.7 Connecting Regenerative Resistors for details.

SGDV (Single Phase, 100 V)

R70

R90

2R1

2R8

Continuous Output Current [Arms]

0.66

0.91

2.1

2.8

Instantaneous Max. Output Current [Arms]

2.1

2.9

6.5

9.3

Regenerative Resistor *

None or external

Main Circuit Power Supply

Single-phase, 100 to 115 VAC

, 50/60 Hz

Control Power Supply

Single-phase, 100 to 115 VAC

, 50/60 Hz

Overvoltage Category

III

+10%

–15%

+10%

–15%

SGDV (Single Phase, 200 V)

120

*1

Continuous Output Current [Arms]

11.6

Instantaneous Max. Output Current [Arms]

28

Regenerative Resistor

*2

Built-in or external

Main Circuit Power Supply

Single-phase, 220 to 230 VAC

, 50/60 Hz

Control Power Supply

Single-phase, 220 to 230 VAC

, 50/60 Hz

Overvoltage Category

III

+10%

–15%

+10%

–15%

SGDV (Three Phase, 200 V) R70 R90 1R6 2R8 3R8 5R5 7R6 120 180 200 330 470 550 590 780

Continuous Output Current

[Arms]

0.66 0.91 1.6

2.8

3.8

5.5

7.6 11.6 18.5 19.6 32.9 46.9 54.7 58.6 78.0

Instantaneous Max. Output

Current [Arms]

2.1

2.9

5.8

9.3 11.0 16.9 17

28

42

56

84

110 130 140 170

Regenerative Resistor

*

None or external

Built-in or external

External

Main Circuit Power Supply

Three-phase, 200 to 230 VAC

, 50/60 Hz

Control Power Supply

Single-phase, 200 to 230 VAC

, 50/60 Hz

Overvoltage Category

III

+10%

–15%

+10%

–15%

Advertising