7.5 Monitoring Safety Input Signals

7-7

7

Moni

to

r Disp

lays (Un

)

7.5 Monitoring Safety Input Signals

The status of safety input signals can be checked with the safety I/O signal monitor (Un015). The procedure

for the method of interpreting the display and a display example are shown below.

7.5.1 Interpreting Safety Input Signal Display Status

The safety I/O signal monitor (Un015) can be read in the following way. The upper level indicates ON, and

the lower level indicates OFF. All undefined digits are shown in the lower level (OFF).

Note: Input signals use the following circuit configuration.

• OFF: Open
• ON: Short-circuited

Example

7.5.2 Safety Input Signal Display Example

Safety input signals are displayed as shown below.

• When the /HWBB1 signal turns OFF to activate the HWBB function

Display LED Number

Input Terminal Name

Signal Name

1

CN8-3, -4

/HWBB1

2

CN8-5, -6

/HWBB2

3

Reserved

4

Reserved

5

Reserved

6

Reserved

7

Reserved

8

Reserved

U n 0 1 5 =

8 7 6 5 4 3 2 1 digit

MECHA

ON (short-circuited)

U n 0 1 5 =

8 7 6 5 4 3 2 1 digit

The first digit is
in the lower level.

MECHA

Advertising