3 Wiring and Connection

3.1.1 Main Circuit Terminals

3-2

3.1 Main Circuit Wiring

The names and specifications of the main circuit terminals are given below.

Also this section describes the general precautions for wiring and precautions under special environments.

3.1.1 Main Circuit Terminals

: Main circuit terminals

46

Terminal

Symbols

Name

Model SGDV-

Specification

L1, L2

Main circuit power in-

put terminals

F

Single-phase 100 to 115 V,
+10% to -15% (50/60 Hz)

L1, L2, L3

A

Three-phase 200 to 230 V,
+10% to -15% (50/60 Hz)

D

Three-phase 380 to 480 V,
+10% to -15% (50/60 Hz)

L1C, L2C

Control power input

terminals

F

Single-phase 100 to 115 V,
+10% to -15% (50/60 Hz)

A

Single-phase 200 to 230 V,
+10% to -15% (50/60 Hz)

24V, 0V

D

24 VDC,

±

15%

B1/ , B2

*1

External regenera-

tive resistor connec-

tion terminals

R70F, R90F, 2R1F,
2R8F, R70A, R90A,
1R6A, 2R8A

If the regenerative capacity is insufficient, connect
an external regenerative resistor between B1/ and
B2.
Note: The external regenerative resistor is not

included.

3R8A, 5R5A, 7R6A,
120A, 180A, 200A,
330A, 1R9D, 3R5D,
5R4D, 8R4D, 120D,
170D

If the internal regenerative resistor is insufficient,
remove the lead or shorting bar between B2 and B3
and connect an external regenerative resistor
between B1/ and B2.
Note: The external regenerative resistor is not

included.

470A, 550A, 590A,
780A, 210D, 260D,
280D, 370D

Connect a regenerative resistor unit between B1/
and B2.
Note: The regenerative resistor unit is not included.