3.3 I/O Signal Allocations

3-21

3

Wi

ring and

C

onne

ctio

n

3.3 I/O Signal Allocations

This section describes the I/O signal allocations.

3.3.1 Input Signal Allocations

Input signals are allocated as shown in the following table.

Refer to the Interpreting the Input Signal Allocation Tables and change the allocations accordingly.

<Interpreting the Input Signal Allocation Tables>

• Inverting the polarity of the forward run prohibited and reverse run prohibited signals

from the factory setting will prevent the overtravel function from working in case of sig-
nal line disconnections or other failures.
If this setting is absolutely necessary, check the operation and confirm that there are
no safety problems.

• When two or more signals are allocated to the same input circuit, input signal level is

valid for all allocated signals, resulting in an unexpected machine operation.

Input Signal Names

and Parameters

Valid-

ity

Level

Input

Signal

CN1 Pin Numbers

Connection Not

Required

(SERVOPACK

judges the connec-

tion)

13

7

8

9

10

11

12

Always

ON

Always

OFF

Forward Run Prohibited

Pn50A.3

H

P-OT

0

1

2

3

4

5

6

7

8

L

/P-OT

9

A

B

C

D

E

F

Level at which input signal
allocations are valid.

The parameter set values to be used are shown.
Signals are allocated to CN1 pins according to the
selected set values.
Values in cells in bold lines are the factory settings.

If always ON (7) or always OFF (8) is set, signals
will be processed in the SERVOPACK, which will
eliminate the need for wiring changes.