5 Adjustments

5.8.3 Current Control Mode Selection Function

5-62

5.8.3 Current Control Mode Selection Function

This function reduces high-frequency noises while the servomotor is being stopped. This function is enabled

by default and set to be effective under different application conditions. Set Pn009.1 = 1 to use this function.

This function can be used with the following SERVOPACKs.

5.8.4 Current Gain Level Setting

This function reduces noises by adjusting the parameter value for current control inside the SERVOPACK

according to the speed loop gain (Pn100). The noise level can be reduced by reducing the current gain level

(Pn13D) from its factory setting of 2000% (disabled). If the set value of Pn13D is decreased, the level of noise
will be lowered, but the response characteristics of the SERVOPACK will also be degraded. Adjust the current

gain level within the allowable range at which SERVOPACK response characteristics can be secured.

5.8.5 Speed Detection Method Selection

This function can ensure smooth movement of the servomotor while the servomotor is running. Set the value
of Pn009.2 to 1 and select speed detection 2 to smooth the movement of the servomotor while the servomotor

is running.

Input Voltage

SERVOPACK Model SGDV-

200 V

120A, 180A, 200A, 330A, 470A, 550A, 590A, 780A

400 V

3R5D, 5R4D, 8R4D, 120D, 170D, 210D, 260D, 280D, 370D

Parameter

Meaning

When Enabled

Classification

Pn009

n.

0

Selects the current control mode 1.

After restart

Tuning

n.

1

[Factory setting] Selects the current control mode 2 (low noise).

• If current control mode 2 is selected, the load ratio may increase while the servomotor

is being stopped.

Pn13D

Current Gain Level

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

100 to 2000

1%

2000

Immediately

Tuning

• If the parameter setting of the current gain level is changed, the responses character-

istics of the speed loop will also change. The SERVOPACK must, therefore, be read-
justed again.

Speed

Position

Parameter

Meaning

When Enabled

Classification

Pn009

n. 0
[Factory setting]

Selects speed detection 1.

After restart

Tuning

n. 1

Selects speed detection 2.

• If the speed detection method is changed, the response characteristics of the speed

loop will change and the SERVOPACK must be readjusted again.