2 "safe torque off active" state, 3 "device is ready to switch on" state, Safe torque off active" state – Lenze 9400 User Manual

Page 100: Device is ready to switch on" state, Safe torque off active, Device is ready to switch on, 4drive interface

Advertising
background image

4

Drive interface

4.3

Device states

100

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.3.2

"Safe torque off active" state

This device state becomes active if the controller receives the "Safe torque off" request by the safety

module.

• "Drive is torqueless" (0x00750003) is entered in the logbook.
• If no corresponding request by the safety module is available, a change to the subsequent state

"Device is ready to switch on" is effected.

4.3.3

"Device is ready to switch on" state

This is the device state of the controller directly after the initialisation has been completed and

where no DC-bus voltage is applied yet.

• The bus systems are running and the terminals and encoders are evaluated.
• The monitoring functions are active.
• The controller can be parameterised and device commands can be executed to a limited extent.
• The functions of the user task can be used.

• Precondition: The application has started (status display in

C02108

).

• The basic drive functions cannot be used yet.

LED DRIVE READY

LED DRIVE ERROR

Display in

C00183

OFF

101: Safe torque off active

Note!

The "Safe torque off active" status is also passed through after an error has been

acknowledged (see illustration

[4-24]

).

LED DRIVE READY

LED DRIVE ERROR

Display in

C00183

OFF

"Device is ready to switch on"

Note!

The "Device is ready to switch on" status is not only activated after mains connection but

also after reset of "Trouble", "Fault", or "Safe torque off active".

• In order to change from the "Device is ready to switch on" to the "Device is switched

on" status when

C00142

= "0: inhibited", at least one of the controller inhibit sources

must be active.

• When

C00142

= "1: Enabled", the "Device is ready to switch on" status directly

changes to the "Device is switched on" status.