C00137 | brake transistor utilisation, C00138 | brake resistor utilisation, C00142 | autom. restart after mains on – Lenze 9400 User Manual

Page 747: C00142, C00137, C00138, 14 parameter reference

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

747

14

Parameter reference

14.2

Parameter list | C00137

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00137

C00138

C00142

Parameter | Name:

C00137 | Brake transistor utilisation

Data type: INTEGER_32

Index: 24438

d

= 5F76

h

From software version V1.5

Braking operation

Display range

(min. value | unit | max. value)

0

%

250

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00138 | Brake resistor utilisation

Data type: INTEGER_32

Index: 24437

d

= 5F75

h

From software version V1.5

Braking operation

Display range

(min. value | unit | max. value)

0

%

250

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00142 | Autom. restart after mains ON

Data type: UNSIGNED_32

Index: 24433

d

= 5F71

h

Starting performance of the controller after mains connection and reset of "Trouble", "Fault" or "Safe torque off

active".

Danger!

• If automatic restart is enabled (

C00142

= "1: Enabled"), the drive can restart automatically from the "Trouble"

and "Safe torque off" device states when the trouble or request for "Safe torque off active" has been eliminated!

• The controller enable generated by the application via a connection of the terminal 28 (RFR) with one of the

digital outputs DIGOUT_bOut(x) is not permissible if the following functions are active:

"Auto-start after mains ON" (

C00142

= "1") and "Program auto-start after mains switching" (

C02104

= "1")

If this is not observed, the controller can start automatically after mains connection!

Automatic restart after mains connection

Activate application

Selection list

(Lenze setting printed in bold)

0 Inhibited
1 Enabled

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising
This manual is related to the following products: