4 activate application, Activate application, 4drive interface – Lenze 9400 User Manual

Page 47

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

47

4

Drive interface

4.2

Device commands

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2.4

Activate application

If several applications are available on the memory module, the

C00002

= "5: Activate application"

device command can be used to activate the application the number of which has been set in

C00005

.

[4-14] "Activate application" function

• Only possible when the application has stopped and the controller is inhibited.
• Whether the application is started at the same time, depends on the auto-start setting selected

in

C02104

.

• After mains switching, the preset application will be loaded into the controller.
• If after mains switching another application than the one preset by Lenze is to be loaded, it must

be activated first and then the selected application must be saved with the device command

"

Save selected application

".

( 48)

.

• The number of the currently active application is displayed in

C00007

.

Possible status displays for this device command

Related device commands

Save selected application

( 48)

Start application

( 53)

/

Stop application

( 54)

* In this example, application selection "2" is set in

C00005

PS

9400

RAM

Firmware

Application

PS

Application 3

Memory module MM

Application 1

Application 2*

PS

Note!

When the application is activated, the corresponding start parameter set is loaded

automatically and parameter settings executed before will get lost unless the parameter

set was saved before!

Status (

C00003

)

Meaning

361730 Device command in process

327680 Device command executed successfully

327681 General fault