2 parameter list, C00002 | device command, C00002 – Lenze 9400 User Manual

Page 720: Ure protection, Ecute device command, T in, C00005, C00003, Ands, C00006

Advertising
background image

14

Parameter reference

14.2

Parameter list

720

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

14.2

Parameter list

This chapter lists all parameters of the operating system in numerically ascending order.

C00002

Note!

The parameter descriptions are based on the software version V12.00.xx.

Parameter | Name:

C00002 | Device command

Data type: UNSIGNED_32

Index: 24573

d

= 5FFD

h

Device commands

C00003

shows the status of the last executed device command.

• Under

C00150

you can query the current status of the device control.

Note:

Before switching off the supply voltage after a device command has been executed, check the successful execution

of the device command via the status display in

C00003

!

The meaning of the status display in

C00003

can be obtained from the subchapter for the corresponding device

command in chapter "

Device commands

".

Selection list

(Lenze setting printed in bold)

Info

0 Load Lenze setting

Resets parameters to Lenze setting.

• Only possible when the application has stopped and

the controller is inhibited.

1 Load start parameters

Loads parameters from the memory module.

• Only possible when the application has stopped and

the controller is inhibited.

2 ENP: Load plant data

Reads plant data from the electronic motor nameplate.

• Only possible when the application has stopped and

the controller is inhibited.

5 Activate application

Activates the application selected under

C00005

.

• Whether the application is also started, depends on

the auto-start setting selected.

• Only possible when the application has stopped.

7 Save selected application

Selects the active application as start application.

11 Save start parameters

Saves parameters fail-safe in the memory module.

20 Delete logbook

Deletes all logbook entries.

21 Archive logbook

Exports logbook entries to file.

27 Device search function ON
28 Device search function OFF
31 Start application
32 Stop application
33 Reset program

Carries out a reset.

• All variables are reset to their initialisation value.

• The situation corresponds to the start of a new

program loaded into the control (cold start).

34 Delete program

Carries out a reset (source).

• All variables are reset to their initialisation value.

• The application program is deleted and the controller

is reset to its original state.

Advertising
This manual is related to the following products: