2 device commands, Device commands, 4drive interface – Lenze 9400 User Manual

Page 42

Advertising
background image

4

Drive interface

4.2

Device commands

42

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2

Device commands

In the following subchapters the device commands of the controller are described, which are

provided in

C00002

and which can be executed by means of the »Engineer« or alternatively with the

keypad when an online connection has been established.

Activating frequently required device commands via the toolbar
The simplest way to execute the frequently required device commands is directly via the Toolbar of

»Engineer« when an online connection has been established.

Note!

Before switching off the supply voltage after a device command has been executed,

check the successful execution of the device command via the status display in

C00003

!

The meaning of the status display in

C00003

can be obtained from the subchapter for

the corresponding device command.

Icon

Function

Enable controller

Inhibit controller

Start application

Inhibit controller

and

Stop application

Note!

Device commands that can be executed via the Toolbar of the »Engineer« always affect

the element currently selected in the Project view including all subelements!

• If no controller but a system module is selected in the Project view, the corresponding

device command will be activated in all lower-level controllers having an online

connection with the »Engineer«.

Before the desired action is carried out, a confirmation prompt appears first, asking

whether the action is really to be carried out.

Advertising