4.2.15

Inhibit controller

The

C00002

= "41: Inhibit controller" device command is used to inhibit the controller ("controller

inhibit"), i.e. the power output stages in the controller are inhibited and the speed/current and

position controllers of the motor control are reset. The motor becomes torqueless and coasts unless

it is already at standstill.

• The controller can also be inhibited by other sources, e.g. via the digital input RFR or through the

application.

C00158

provides a bit coded representation of all active sources/triggers of a controller inhibit.

Tip!

This device command can also be activated via the

icon in the Toolbar.

Related device commands

Enable controller

( 61)

Note!

This device command has no status display in

C00003

, i.e. the display remains

unchanged showing the previous device command status.