16 enable controller, Enable controller, 4drive interface – Lenze 9400 User Manual

Page 61

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

61

4

Drive interface

4.2

Device commands

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2.16

Enable controller

The

C00002

= "42: Enable controller" device command is used to re-enable an inhibited controller.

Tip!

This device command can also be activated via the

icon in the Toolbar.

Related device commands

Inhibit controller

( 60)

Note!

Please note that the controller will only be enabled if all sources for controller inhibit are

reset!

C00158

provides a bit coded representation of all active sources/triggers of a

controller inhibit.

This device command has no status display in

C00003

, i.e. the display remains

unchanged showing the previous device command status.

Advertising