5 save selected application, Save selected application, 4drive interface – Lenze 9400 User Manual

Page 48

Advertising
background image

4

Drive interface

4.2

Device commands

48

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2.5

Save selected application

After mains switching the controller always loads the preset start application from the memory

module, even if a different application has been active before.
With the device command

C00002

= "7: Save selected application" the active application can be

defined as start application.

[4-15] "Save selected application" function

• When this device command is executed, the parameter set is also saved automatically.
• The number of the currently active application is displayed in

C00007

.

Possible status displays for this device command

Related device commands

Activate application

( 47)

Start application

( 53)

Stop application

( 54)

* In this example, the active application 2 is defined as start application

PS

9400

RAM

Firmware

Application 2*

PS

Application 3

Memory module MM

Application 1

Application 2*

PS

Status (

C00003

)

Meaning

492802 Device command in process

458752 Device command executed successfully

458753 General fault