2 select motor control, Select motor control, 5motor interface – Lenze 9400 User Manual

Page 121

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

121

5

Motor interface

5.2

Select motor control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2

Select motor control

In

C00006

the motor control is selected; the default is the servo control for synchronous motors.

Function extension from software version V3.0:

From software version V3.0, alternatively to the servo control also the V/f control and the sensorless

vector control are provided as control types in

C00006

:

• The V/f control is the classic operating mode for standard applications.
• Compared to the V/f control, improved drive characteristics can be achieved with sensorless

vector control by:

• a higher torque across the entire speed range
• a higher speed accuracy and a higher concentricity factor
• Higher efficiency

[5-1]

Comparison of V/f control and sensorless vector control

Open/closed loop control

Detailed information

1 SC: Servo control for synchronous motor

Servo control (SC) ( 142)

2 SC: Servo control for asynchronous motor

4 SLVC: Sensorless vector control

Sensorless vector control (SLVC) ( 163)

6 VFCplus: V/f control open loop

V/f control (VFCplus) ( 181)

7 VFCplus: V/f control closed loop

V/f control (VFCplus) ( 197)

V/f control

Sensorless vector control

M

n

n

N

M

N

Œ



Note!

Sensorless vector control (SLVC) is only approved for powers up to 55 kW and horizontal

applications (no hoists or lifting equipment)!

Advertising
This manual is related to the following products: