5

Motor interface

5.6

V/f control (VFCplus)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.6.1.3

Parameterising load adjustment

C00962

serves to parameterise a load adjustment in [%] proportionally to the rated torque to obtain

a correspondingly "rigid "drive behaviour even after the starting action.

• When starting torque = rated torque, a load adjustment of 50 % is suitable for most

applications.

The

C00961

parameter serves to adjust the characteristic depending on the load at CW and CCW

rotation:

Short overview: Parameters for load adjustment

Stop!

If the load adjustment is too high, the motor current may increase in idle state and the

motor may overheat!

Setting in C00961

Info

0: CW rotation in motor mode/CCW rotation in motor

mode

The motor operates in motor mode in both directions.

1: CW rotation in motor mode/CCW rotation in

generator mode

Application example: Hoist without counterweight

2: CW rotation in generator mode/CCW rotation in

motor mode

Application example: Dancer-controlled unwinder

Parameter

Info

Lenze setting

Value Unit

C00961

VFC: Load - cw/ccw-operation

CW: mot. / CCW: mot.

C00962

VFC: Load adjustment

20.00 %