1 "ls_ssiencoderx8" system block, Ed to the application via the, Ls_ssiencoderx8 – Lenze 9400 User Manual

Page 253: 6encoder evaluation

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

253

6

Encoder evaluation

6.3

Parameter setting

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.3.8.1

"LS_SsiEncoderX8" system block

The LS_SsiEncoderX8 system block provides the SSI data words received to the application for

further processing in the function block editor.

Outputs

Gray-binary conversion
If an SSI encoder with Gray coding is used, a data conversion of Gray-to-binary code can be

connected in

C00437/1...8

individually for each output of the LS_SsiEncoderX8 SB, and thus for each

partword.

• In the Lenze setting "Binary coded" there is no conversion, i. e. an SSI encoder with binary coding

is expected.

Note!

• The LS_SsiEncoderX8 SB is only provided within controllers with a MM3xx or MM4xx

memory module.

• If a position is transmitted in the SSI data word, it is output in an unchanged manner

with regard to the position format by the LS_SsiEncoderX8 SB. For a use of the SSI

encoder as position encoder the position has to be converted into the 9400 format

afterwards by means of the L_EsEncoderConv FB.

Identifier

Data type

Value/meaning

SSI_dwDataword_1

DWORD

SSI partword 1

• In the Lenze setting the complete SSI data word received is shown at this output

without a conversion of the data format.

SSI_dwDataword_2

...

SSI_dwDataword_8

DWORD

SSI partwords 2 ... 8

• In the Lenze setting these outputs are deactivated.

Division of the SSI data word into partwords ( 254)

C00435/2

C00436/2

Start position

Length

C00435/1

C00436/1

C00435/3

C00436/3

C00435/4

C00436/4

C00435/5

C00436/5

C00435/6

C00436/6

C00435/7

C00436/7

C00435/8

C00436/8

Partword 1

Partword 2

Partword 3

Partword 4

Partword 5

Partword 6

Partword 7

Partword 8

C00437/2

Coding

C00437/1

C00437/3

C00437/4

C00437/5

C00437/6

C00437/7

C00437/8

C00424 Dataword length

C00423

Bitrate

C00422

Encoder type

C00421

Encoder voltage

SSI
dataword

LS_SsiEncoderX8

SSI_dwDataword_1

SSI_dwDataword_2

SSI_dwDataword_3

SSI_dwDataword_4

SSI_dwDataword_5

SSI_dwDataword_6

SSI_dwDataword_7

SSI_dwDataword_8

S

31