11.3

Quick stop

In contrast to

Stop

, the purpose of quick stop (QSP) is a stop in case of error. If quick stop is activated,

the drive is brought to standstill within the deceleration time set irrespective of the setpoint that is

preselected.

Tip!
Quick stop can also be set as error response for many monitoring functions ("quick stop by

trouble"). Detailed information can be found in the chapter "

Diagnostics & fault analysis

".

( 598)

The source from which the quick stop was activated is shown in a bit coded manner in

C00159

.

11.3.1

Internal interfaces | "LS_Quickstop" system block"

The LS_Quickstop system block provides the internal interfaces for the basic function "Stop" in the

function block editor.

Note!

Through this, superimposed controls (e.g. synchronous or position control) may produce

following errors. If several drives execute a coordinated motion, the quick stop function

should only be used for the motion master (master drive) in order to maintain the

coordination.
When the basic function is activated, a start acceleration is considered.

Start

acceleration/acceleration reduction when the basic function changes

( 380)

Note!

Ensure that the system block is called in a cyclic application task.
Basically, projects which only contain an unsolicited task and no cyclic task are not

permissible!

LS_Quickstop

QSP_bActivate1

QSP_bActive

STOP

n

t

³ 1

QSP_bActivate2

QSP_bActivate3

QSP_bActivateDCBrake