3 executing manual jogging, 11 basic drive functions – Lenze 9400 User Manual

Page 401

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

401

11

Basic drive functions

11.4

Manual jog

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.4.3

Executing manual jogging

Requirements

• The controller is in the "Operation" device state.
• The basic function "manual jog" is part of the active application.
• No other basic function is active.

Activation
To request the control via the basic function, the MAN_bEnable enable input in the application must

be set to TRUE.

• If no other basic function is active, a change-over to the "Manual jog active" function state is

effected and manual jog can be carried out via the control inputs.

• A successful change to the function state "Manual jog active" is displayed by a TRUE signal at

the MAN_bEnabled status output.

Deactivation
If the MAN_bEnable enable input is reset to FALSE, an active manual jog is reset, i.e. the control

inputs for manual jog are inhibited and the drive is braked to standstill within the deceleration time

for

Stop

.

( 384)

• The status output MAN_bEnabled is reset to FALSE and a change-over from the active "Manual

jog active" function state via the "Drive is stopped" function state back to the basic state "Drive

at standstill" is carried out.

Advertising