Mode 1003: ds402 homing method 03, 11 basic drive functions – Lenze 9400 User Manual

Page 444

Advertising
background image

11

Basic drive functions

11.6

Homing

444

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Mode 1003: DS402 homing method 03

Procedures:

Case 1:

Axis has not yet activated the reference switch:

1. Movement in positive direction with profile data set 1.
2. Reversing with positive edge of the reference switch and change to profile data set 2.
3. Negative edge of the reference switch activates touch probe detection.
4. The following positive edge of the encoder zero pulse/touch probe sensor sets the reference.
5. Absolute positioning to target position (

C02643

) with profile data set 2 (if

C02641

= "0").

Case 2:

Axis already stands on the reference switch:

1. Movement in negative direction with profile data set 2.
2. Negative edge of the reference switch activates touch probe detection.
3. The following positive edge of the encoder zero pulse/touch probe sensor sets the reference.
4. Absolute positioning to target position (

C02643

) with profile data set 2 (if

C02641

= "0").

 Touch probe/zero pulse

 Reference switch

1

2

0

1

Advertising
This manual is related to the following products: