C02641 | action after detect home position, C02642 | home position, C02643 | homing: target position – Lenze 9400 User Manual

Page 874: C02644 | homing: speed 1, C02642, C02643, C02644, C02641, Serves, Tting

Advertising
background image

14

Parameter reference

14.2

Parameter list | C02641

874

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02641

C02642

C02643

C02644

1028 DS402 homing method 28
1029 DS402 homing method 29
1030 DS402 homing method 30
1031 DS402 homing method 31
1032 DS402 homing method 32
1033 DS402 homing method 33
1034 DS402 homing method 34
1035 DS402 homing method 35

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02640 | Homing mode

Data type: UNSIGNED_32

Index: 21935

d

= 55AF

h

Parameter | Name:

C02641 | Action after detect Home position

Data type: UNSIGNED_32

Index: 21934

d

= 55AE

h

From software version V4.0

Basic function "

Homing

"

Selection list

(Lenze setting printed in bold)

0 Move absolute on target position
1 Move relative by Target position
2 Stop immediately

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02642 | Home position

Data type: INTEGER_32

Index: 21933

d

= 55AD

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

-214748.3647

Unit

214748.3647 0.0000 Unit

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02643 | Homing: Target position

Data type: INTEGER_32

Index: 21932

d

= 55AC

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

-214748.3647

Unit

214748.3647 0.0000 Unit

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02644 | Homing: Speed 1

Data type: INTEGER_32

Index: 21931

d

= 55AB

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s

214748.3647 360.0000 Unit/s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Advertising