11.6

Homing

With the basic function "Homing" the measuring system of the machine is transmitted to the

controller within the travel range that is physically possible.

• The reference (e.g. zero position of the drive axis in the machine measuring system) can be

defined by reference search or reference setting.

• In case of reference search, the drive travels according to the defined homing mode to detect

the reference in the measuring system independently.

• In the reference point, the home position parameterised in

C02642

is set as the current

position. Afterwards, an absolute positioning to the target position parameterised in

C02643

takes place (if

C02641

= "0").

• If the reference is set in the homing mode "100: Set reference directly" or via the control input

HM_bLoadHomePos, the drive can also be referenced manually if the motor is at standstill. The

measuring system is set by means of the home position parameterised in

C02642

or applied at

the input HM_dnHomePos_p.

Danger!

During homing, specially assigned profile parameters are active. If they have not been

set correctly, the drive can engage in uncontrolled movement!

Note!

Normally homing is only required once during commissioning of systems for which the

machine cycle can be represented in the display area of the encoder, e. g. if multiturn

absolute value encoders or singleturn absolute value encoders/resolvers are used during

the machine cycle on one motor revolution.

• The encoder position is stored safe against mains failure in the memory module and

is therefore known to the drive control even after the mains has been

switched.

Behaviour of the home position after mains switching

( 421)

• A renewed reference setting is only required in case of a renewed commissioning or

in case of service (e.g. when drive components are exchanged).

• When multipole resolvers (

C00080

> 1) are used, a renewed homing is required after

mains switching due to the ambiguity of the evaluated position.