C00078

C00079

C00080

C00081

C00082

C00083

Parameter | Name:

C00078 | Field contr. reset time

Data type: UNSIGNED_32

Index: 24497

d

= 5FB1

h

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

ms

6000.0 15.1 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00079 | Motor - mutual inductance

Data type: UNSIGNED_32

Index: 24496

d

= 5FB0

h

Display range

(min. value | unit | max. value)

0.0

mH

214748364.7

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00080 | Resolver - number of pole pairs

Data type: UNSIGNED_32

Index: 24495

d

= 5FAF

h

Adaptation of the resolver evaluation dynamics

Homing

Behaviour of the home position after mains switching

Setting range

(min. value | unit | max. value)

Lenze setting

1

10 1

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00081 | Rated motor power

Data type: UNSIGNED_32

Index: 24494

d

= 5FAE

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.01

kW

500.00 0.25 kW

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00082 | Motor rotor resistance

Data type: UNSIGNED_32

Index: 24493

d

= 5FAD

h

Display range

(min. value | unit | max. value)

0.0000

Ohm

214748.3647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C00083 | Motor rotor time constant

Data type: UNSIGNED_32

Index: 24492

d

= 5FAC

h

Display range

(min. value | unit | max. value)

0.00

ms

21474836.47

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100