Mode 1015: ds402 homing method 15, Mode 1016: ds402 homing method 16, Mode 1017: ds402 homing method 17 – Lenze 9400 User Manual

Page 457: Mode 1018: ds402 homing method 18, 11 basic drive functions

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

457

11

Basic drive functions

11.6

Homing

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Mode 1015: DS402 homing method 15

Reserved: no homing is executed.

Mode 1016: DS402 homing method 16

Reserved: no homing is executed.

Mode 1017: DS402 homing method 17

Procedure:

1. Movement in negative direction with profile data set 1.
2. Reversing to negative travel range limit switch and change to profile data set 2.
3. The following negative edge of the travel range limit switch sets the reference.
4. Absolute positioning to target position (

C02643

) with profile data set 2 (if

C02641

= "0").

Mode 1018: DS402 homing method 18

Procedure:

1. Movement in positive direction with profile data set 1.
2. Reversing to positive travel range limit switch and change to profile data set 2.
3. The following negative edge of the travel range limit switch sets the reference.
4. Absolute positioning to target position (

C02643

) with profile data set 2 (if

C02641

= "0").

 Negative travel range limit switch

1

0

 Positive travel range limit switch

1

0