2 loading home position via input, 11 basic drive functions – Lenze 9400 User Manual

Page 472

Advertising
background image

11

Basic drive functions

11.6

Homing

472

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.6.5.1

Starting reference search/setting the reference directly

By setting the HM_bActivateHoming control input to TRUE, the reference search in the selected

homing mode is started.

• During reference search, the HM_bActive status output is set to TRUE.
• By setting the status output HM_bHomePosAvailable to TRUE, it is already signalised during the

reference search that the home position has been found. Depending on the homing mode

selected, the drive traverses further on to the target position set in

C02643

.

• When the reference search is completed, the HM_bActive status output is reset to FALSE and the

HM_bDone status output is set to TRUE.

11.6.5.2

Loading home position via input

By setting the control input HM_bLoadHomePos to TRUE, the "Tool position" that is pending at input

HM_dnHomePos_p is manually accepted as home position during the drive is at standstill. This is

also possible if the controller is inhibited.

• The HM_bDone status output is set to TRUE for one cycle.
• The HM_bHomePosAvailable status output is set to TRUE.

Note!

In the homing mode "100: Set reference directly" no reference search is started, but the

home position set in

C02642

is directly accepted.

Note!

For the encoderless motor control types

(from software version V3.0)

the following

applies:
If V/f control or sensorless vector control has been selected, this function is only effective

if the position controller has also been selected for the position control

(

C02570

= "2: position controller active").

For the encoderless motor control types

(from software version V5.0)

the following

applies:
If the V/f control or sensorless vector control is selected, this function can be activated

irrespective of the use of the position controller.

Advertising
This manual is related to the following products: