11

Basic drive functions

11.12

Brake control

532

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.12.2.6 Torque feedforward control

In automatic operation (mode 2/12) the brake control offers the possibility of precontrolling the

required torque of the drive when the brake is released.

Via

C02588

first the basic selection on whether a parameterised starting torque or the torque

memorised during the last application process is to be used for the feedforward control.

Feedforward control with parameterised starting torque

[11-38] Feedforward control with parameterised starting torque

Note!

The torque is precontrolled for one second. During this time, the actual torque must have

reached 90 % of the set torque, otherwise a fault is tripped!
The torque feedforward control is also supported for the V/f control

(from software

version V3.0)

.

C02586

: Starting torque 1

C02587

: Starting torque 2

C02588

: Source of starting torque

• When

C02588

= 0, a change-over between

two starting torques is possible via input

BRK_bStartingTorque2:

BRK_bStartingTorque2 = FALSE: Starting

torque 1 (

C02586

) is used.

BRK_bStartingTorque2 = TRUE: Starting

torque 2 (

C02587

) is used.

1

0

BRK_bStartingTorque2

C02586

Œ


C02587

1

0

C02588 = 0

Ž

S&H

CTRL

Speed controller

Advertising