2 online change mode, Online change, Online change mode – Lenze 9400 User Manual

Page 562: 11 basic drive functions

Advertising
background image

11

Basic drive functions

11.13

Cam data management

562

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.13.3.2 Online change mode

During running operation, new cam data can be downloaded from »Engineer« to the controller if

the controller is in storage mode 1 or 2.

• If the cam data are provided with an access protection, the user password has to be entered first.

Access protection

( 555)

• The time when the new/altered cam data are accepted depends on the online change mode set

in

C02905

.

Mode 16: Automatic activation with CINH
In the Lenze setting, the online change mode "Automatic activation with CINH" is set in

C02905

, i.e.

the new cam data are accepted automatically as soon as the controller is inhibited.

[11-49] Online change mode "Automatic activation with CINH"

Note!

If the controller is in storage mode 3, the "Online change" function is deactivated:

• The online change mode set in

C02905

is ineffective.

• In

C02906

the status "999: Online change deactivated" is displayed.

• For the download of new cam data, controller inhibit is required.
• The cam data are accepted immediately after download.

Memory distribution

( 554)

Download/change of cam data active

Internal recalculation of cam data active

Automatic activation with controller inhibit

W

&$0BE$FWLYDWH1HZ'DWD

W

&$0BE%XV\

W

&$0BE1HZ'DWD$YDLODEOH

W

2QOLQHFKDQJH

W

&DPGDWD%

&DPGDWD$

n

o

W

&,1+

p

Advertising