C02902 | timestamp, C02903 | guid, C02905 | online change mode – Lenze 9400 User Manual

Page 905: C02905, Set in, C02902, C02903, 14 parameter reference

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

905

14

Parameter reference

14.2

Parameter list | C02902

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02902

C02903

C02905

Parameter | Name:

C02902 | Timestamp

Data type: UNSIGNED_32

Index: 21673

d

= 54A9

h

From software version V3.0

Basic function "

Cam data management

"

Display range

(min. value | unit | max. value)

0

4294967295

Subcodes

Info

C02902/1

Time stamp of the cam data in the controller

C02902/2

Time stamp of the cam data which are currently being

processed in the controller.

C02902/3

Time stamp of the cam data in the controller which have

already been converted into the internal format.

C02902/4

Time stamp of the cam data in the memory module

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02903 | GUID

Data type: OCTET_STRING

Index: 21672

d

= 54A8

h

From software version V3.0

Basic function "

Cam data management

"

Display range

(min. value | unit | max. value)

Subcodes

Info

C02903/1

GUID of the cam data in the controller

C02903/2

GUID of the cam data which are currently being

processed in the controller.

C02903/3

GUID of the cam data in the controller which have

already been converted into the internal format.

C02903/4

GUID of the cam data in the memory module

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02905 | Online Change Mode

Data type: UNSIGNED_32

Index: 21670

d

= 54A6

h

From software version V3.0

Basic function "Cam data management":

Online change mode

Selection list

(Lenze setting printed in bold)

10 Manual activation
15 Automatic activation
16 Automatic activation with controller

inhibit

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising
This manual is related to the following products: