Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

57

4

Drive interface

4.2

Device commands

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2.13

Restart program

The

C00002

= "35: Restart program" device command is used to restart the application program in

the controller.

• All variables except the RETAIN variables are reset to their initialisation value.
• The situation corresponds to a power failure or switching the controller off/on (warm start)

while the program is running.

Possible status displays for this device command

Related device commands

Reset program

( 55)

Delete program

( 56)

Status (

C00003

)

Meaning

2327810 Device command in process

2293760 Device command executed successfully

2293761 General fault