4 operation, 1 selecting the variables to be recorded, Oscilloscope toolbar – Lenze 9400 User Manual

Page 582: Selecting the variables to be recorded, 12 oscilloscope

Advertising
background image

12

Oscilloscope

12.4

Operation

582

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Oscilloscope toolbar

12.4

Operation

This chapter describes step-by-step how to record the signal characteristics of controller variables

and represent, analyse, document and process them in the oscilloscope.

12.4.1

Selecting the variables to be recorded

The oscilloscope supports up to eight channels, i.e. max. eight variables can be recorded in a data

record.

How to add a variable for recording::

1. Double-click the line highlighted in grey in the Vertical channel settings list field.
2. Select the desired variable in the Select variable.
3. Click OK.

• The dialog box is closed and the selection is accepted.

4. Repeat steps 1 ... 3 to select up to seven more variables to be recorded.

The selected variables are displayed in the Vertical channel settings list field. Click into a field to

change the corresponding setting:

Icon

Function

Loading an oscillogram ( 592)

Closing an oscillogram ( 593)

Saving the oscillogram ( 591)

Copy to clipboard: Copy as text | Copy as picture

• For documentation purposes, it is possible to copy the measured data of a data record as a table

or, alternatively, the oscilloscope user interface as a picture, to the clipboard for use in other

programs.

Printer settings | Print view | Print

Activate zoom function

Adjusting the representation ( 587)

Activate automatic scaling function

Adjusting the representation ( 587)

Load recorded oscillogram from device

• Transfer data from the measured data memory of the controller to the Engineering PC as data

record.

• Only possible when an online connection has been established to the controller.

Note!

The configuration of the oscilloscope and the start of recording are only possible when

an online connection has been established to the controller.

Advertising