Fault in the control configuration [0x006a0017, 0x006a0017, 0x006a0016 – Lenze 9400 User Manual

Page 639: 0x006a001a, 13 diagnostics & fault analysis

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

639

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

PDO mapping (MXI2): Faulty configuration [0x006a0016]

Fault in the control configuration [0x006a0017]

Retain memory of the application faulty [0x006a001a]

Module ID (decimal)

Error ID (decimal)

106: Runtime environment for IEC 61131-3 programs

22

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

CANopen communication module in MXI2: Incorrectly

configured process data mapping.

• The corresponding PDO channel is not installed, e. g.

because no communication module was selected for

module slot MXI2 in the Engineer project.

• The communication module selected for module slot

MXI2 in the Engineer project does not support PDO

mapping.

• The mapping information downloaded to the

controller is faulty.

• Integrate suitable communication module for

module slot MXI2 in the Engineer project.

• Check the configuration of the network. Then

recompile the project and transmit it to the controller.

Module ID (decimal)

Error ID (decimal)

106: Runtime environment for IEC 61131-3 programs

23

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

An invalid control configuration has occurred.

Load a different application.

Module ID (decimal)

Error ID (decimal)

106: Runtime environment for IEC 61131-3 programs

26

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

During reading or saving the retain memory of the

application a fault has occurred.

Check whether the memory module suitable for the

application is plugged in.

Mains switching.

(

C00002

) = 33 (reset program).

Carry out project download again.

• Please contact Lenze if the problem occurs again.