Saving of parameters failed [0x00900006, Parameter set: version conflict [0x00900007, Code number duplicated [0x00900008 – Lenze 9400 User Manual

Page 677: 0x00900008, 0x00900009, 0x00900007, 0x00900006, 13 diagnostics & fault analysis

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

677

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Saving of parameters failed [0x00900006]

Parameter set: Version conflict [0x00900007]

Code number duplicated [0x00900008]

Parameter set: Type of standard device has been changed [0x00900009]

Module ID (decimal)

Error ID (decimal)

144: Parameter manager

6

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

An error has occurred while saving the current

parameter set.

Use a different memory module.

Module ID (decimal)

Error ID (decimal)

144: Parameter manager

7

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The parameter set version on the memory module is not

compatible with the firmware of the controller.

Transfer parameter set from Engineer to the controller

and save with

C00002

="11".

Module ID (decimal)

Error ID (decimal)

144: Parameter manager

8

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Code number of the operating system has been assigned

to the application.

Eliminate error in the application and retransfer

application to controller.

Module ID (decimal)

Error ID (decimal)

144: Parameter manager

9

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The firmware has loaded a parameter set the type code

of which does not correspond to the type code of the

controller.

Load a suitable parameter set.

Advertising