No parameters for module in mxi1 [0x0090000a, No parameters for module in mxi2 [0x0090000b, Mains voltage is switched on [0x00910000 – Lenze 9400 User Manual

Page 678: 0x0090000c, 0x00910000, 0x0090000a, 0x0090000b, 13 diagnostics & fault analysis

Advertising
background image

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

678

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

No parameters for module in MXI1 [0x0090000a]

No parameters for module in MXI2 [0x0090000b]

Disconnection in the case of par. storage [0x0090000c]

Mains voltage is switched on [0x00910000]

Module ID (decimal)

Error ID (decimal)

144: Parameter manager

10

Response (Lenze setting printed in bold)

Setting:

C00615/2

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The parameter set contains no parameters for the

module inserted in MXI1.

Integrate the module inserted in MXI1 into the Engineer

project and then retransmit the parameter set to the

controller.

Module ID (decimal)

Error ID (decimal)

144: Parameter manager

11

Response (Lenze setting printed in bold)

Setting:

C00615/3

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The parameter set contains no parameters for the

module inserted in MXI2.

Integrate the module inserted in MXI2 into the Engineer

project and then retransmit the parameter set to the

controller.

Module ID (decimal)

Error ID (decimal)

144: Parameter manager

12

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The supply voltage has failed before the saving of the

parameter set could be completed. In the case of a device

replacement/firmware update, the parameter set can no

longer be established automatically.

Save the start parameters again, and in doing this,

ensure that the supply voltage is applied until the saving

process has been completed. Afterwards acknowledge

the error message with "Reset error".

Module ID (decimal)

Error ID (decimal)

145: Lenze runtime system

0

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Mains voltage has been switched on.

- (Information only)