23 load lenze inv characteristic, 4drive interface – Lenze 9400 User Manual

Page 69

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

69

4

Drive interface

4.2

Device commands

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2.23

Load Lenze INV characteristic

This function extension is available from software version V4.0!

If determination of the so-called "inverter error characteristic" is not possible with the device

command "

Calculate inv. characteristic

" or leads to incorrect results, the device command

C00002

= "70: Load Lenze INV characteristic" can be used to load a characteristic which is typical of

the device in question.

• Only possible when the controller is inhibited.

Tip!
Detailed information about the determination of the inverter error characteristic can be

found in the chapter "Motor interface" in the subchapter "

Optimising the switching

performance of the inverter

".

( 135)

Possible status displays for this device command

Related device commands

Calculate inv. characteristic

( 70)

Status (

C00003

)

Meaning

4621570 Device command in process

4587520 Device command executed successfully

4587521 General fault

Advertising