CAN module (MXI2): Invalid node address 0 [0x00ac0001]

CAN module (MXI2): Basic configuration invalid [0x00ac0002]

CAN module (MXI2): Heartbeat error index 1 ... 32 [0x00ad0000 ... 0x00ad001f]

Module ID (decimal)

Error ID (decimal)

172: CAN module in MXI2: CAN dispatcher

1

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

CANopen communication module in MXI2: Initialisation

error

• The hardware allocation of the node address was

selected via DIP switches, and the DIP switches of the

node address are all on zero.

Note: Instead of the impermissible node address 0, node

address 1 is used.

• Set a non-zero node address by means of the DIP

switches and then switch mains.

• Activation of the software allocation of the node

number by switching over DIP switch 2, then switch

mains.

Module ID (decimal)

Error ID (decimal)

172: CAN module in MXI2: CAN dispatcher

2

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

CANopen communication module in MXI2:

Configuration error

• Faulty download of an Engineer or PLC Designer

project

• Invalid CAN settings according to DS301V402 in the

Engineer or PLC Designer.

• Repeat download

• Correct CAN settings in the project and regenerate

project.

Module ID (decimal)

Error ID (decimal)

173: CAN module in MXI2: CAN-NMT handler

0 ... 31

Response (Lenze setting printed in bold)

Setting:

C14613/1...32

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

CANopen communication module in MXI2: Cyclic node

monitoring

• Node station has not received a heartbeat telegram

from node 1 ... 32 within the defined time.

• Reactivate CAN node by mains switching, restart of

the controller (

C00002

="11000") or CAN reset node.

• Select a different heartbeat producer monitoring

time or switch off monitoring and reset locked error

status, if necessary.

Tip: Save the current parameter set before mains

switching and restart of the controller (

C00002

="11").