C00174

C00175

C00176

C00177

C00178

C00179

Parameter | Name:

C00174 | Undervoltage (LU) threshold

Data type: UNSIGNED_32

Index: 24401

d

= 5F51

h

When

C00173

= 4 ... 7, the undervoltage threshold (LU) can be freely selected.

Note:

The minimum adjustable undervoltage threshold depends on the device type:

• Single-axis controller (Single Drive) up to and including BF7: 210 V

• Single-axis controller (Single Drive) from BF8s: 400 V

• Multi-axis controller (Multi Drive): 15 V

In the case of an offline parameter setting or when exchanging the memory module between different 9400

HighLine device types, always check the setting of this parameter and adapt it, if required, to prevent a parameter

error after the parameter set download or module change!
Setting range

(min. value | unit | max. value)

Lenze setting

15

V

400 285 V

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00175 | Service code

Data type: UNSIGNED_32

Index: 24400

d

= 5F50

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00176 | Service code

Data type: UNSIGNED_32

Index: 24399

d

= 5F4F

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00177 | Service code

Data type: UNSIGNED_32

Index: 24398

d

= 5F4E

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00178 | Elapsed-hour meter

Data type: UNSIGNED_32

Index: 24397

d

= 5F4D

h

Display range

(min. value | unit | max. value)

0

s

4294967295

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00179 | Power-on time meter

Data type: UNSIGNED_32

Index: 24396

d

= 5F4C

h

Display range

(min. value | unit | max. value)

0

s

4294967295

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1