29 can module: reset node, 4drive interface – Lenze 9400 User Manual

Page 76

Advertising
background image

4

Drive interface

4.2

Device commands

76

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2.29

CAN module: Reset node

The

C00002

= "92: CAN module: reset node" device command is used to reinitialise the CANopen

interface of a CANopen communication module in module slot MXI1 or MXI2, which is required, for

instance, after the data transfer rate, node address, or identifiers have been changed.

Tip!
Detailed information on the CANopen communication module (E94AYCCA) can be found in

the "CAN" Communication Manual.

Possible status displays for this device command

Related device commands

CAN module: Pred.Connect.Set

( 78)

CAN module: Identify node

( 80)

Status (

C00003

)

Meaning

6063362 Device command in process

6029312 Device command executed successfully

6029313 General fault
6068736 CAN fault

...

6068991 CAN fault

Advertising
This manual is related to the following products: