C00350

C00351

C00352

Parameter | Name:

C00350 | CAN node address

Data type: UNSIGNED_8

Index: 24225

d

= 5EA1

h

• A change in the node address will not be effective until a CAN Reset Node is performed.

• The basic server channel RX/TX is automatically provided by the node address (

C00372

and

C00373

; subcode 1).

• Overwriting the value deactivates a possibly existing node address selection entered by means of hardware.

"CAN on board" system bus

Setting range

(min. value | unit | max. value)

Lenze setting

1

127 1

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00351 | CAN baud rate

Data type: UNSIGNED_8

Index: 24224

d

= 5EA0

h

• A change in the baud rate will not be effective until a CAN Reset Node is performed.

• Overwriting the value deactivates a possibly existing node address selection entered by means of hardware.

"CAN on board" system bus

Selection list

(Lenze setting printed in bold)

0 500 kbps
1 250 kbps
2 125 kbps
3 50 kbps
4 1 Mbps
5 20 kbps
6 10 kbps
8 Reserved
9 Reserved

10 Reserved
11 Reserved
12 Reserved
13 Reserved
14 800 kbps
15 Reserved

255 Automatic recognition

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00352 | CAN slave/master

Data type: UNSIGNED_8

Index: 24223

d

= 5E9F

h

The drive starts as CAN master after mains switching if a value of "1" has been entered and saved here.

"CAN on board" system bus

Selection list

(Lenze setting printed in bold)

0 Slave
1 Master

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1