C00373 | can sdo server tx identifier, C00373, And the – Lenze 9400 User Manual

Page 777: C00373/1, C00373/2, 14 parameter reference

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

777

14

Parameter reference

14.2

Parameter list | C00373

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00373

Parameter | Name:

C00373 | CAN SDO server Tx identifier

Data type: BITFIELD_32

Index: 24202

d

= 5E8A

h

Identifier with which the assigned SDO server is able to transmit.

• If bit 31 is set (0x8nnnnnnn), the corresponding SDO server is deactivated.

• Mapping of the CANopen objects

I-1200/2

...

I-1209/2

(see DS301 V4.02).

"CAN on board" system bus

Setting range
0x00000000

0xFFFFFFFF

Value is bit-coded:

Info

Bit 0 COB-ID bit 0

• Bit 0 ... 10: COB-ID

• Bit 11 ... 30: Reserved

• Bit 31: SDO invalid

... ...

Bit 31 SDO invalid

Subcodes

Lenze setting

Info

C00373/1

0x00000581

SDO server channel 1 TX

• Subcode 1 contains the basic SDO channel which can

neither be changed nor deactivated, according to

DS301 V4.02. Writing to the subcode has no effect.

• The value under subcode 1 results from the node

address (

C00350

) + 0x580.

C00373/2

0x80000000

SDO server channel 2 TX

C00373/3

0x80000000

SDO server channel 3 TX

C00373/4

0x80000000

SDO server channel 4 TX

C00373/5

0x80000000

SDO server channel 5 TX

C00373/6

0x80000000

SDO server channel 6 TX

C00373/7

0x80000000

SDO server channel 7 TX

C00373/8

0x80000000

SDO server channel 8 TX

C00373/9

0x80000000

SDO server channel 9 TX

C00373/10

0x80000000

SDO server channel 10 TX

Read access  Write access  CINH  PLC STOP  No transfer