Page 800: C00596, And select the error response, C00594, C00595, 14 parameter reference

Advertising
background image

14

Parameter reference

14.2

Parameter list | C00594

800

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00594

C00595

C00596

Parameter | Name:

C00594 | Resp. temp. sensor motor X7/X8

Data type: UNSIGNED_32

Index: 23981

d

= 5DAD

h

Response to motor temperature sensor error.

• The response to a too high motor temperature via PTC input T1/T2 can be selected in

C00585

.

Motor temperature monitoring

Selection list

(Lenze setting printed in bold)

1 Fault
5 Warning
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00595 | Resp. to CAN bus OFF

Data type: UNSIGNED_8

Index: 23980

d

= 5DAC

h

Response if CAN node switches to the bus off state.

"CAN on board" system bus

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00596 | Threshold max. speed reached

Data type: UNSIGNED_32

Index: 23979

d

= 5DAB

h

Threshold for speed monitoring

• The response to reaching the threshold can be selected in

C00607

.

Setting range

(min. value | unit | max. value)

Lenze setting

50

rpm

50000 6500 rpm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising