C00597 | resp. to motor phase failure, C00598 | resp. to open circuit ain1, C00599 | motor phase failure threshold – Lenze 9400 User Manual

Page 801: C00600 | resp. to dc bus overvoltage, C00597, C00599, Threshold parameterised in, T in, C00600, Under

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

801

14

Parameter reference

14.2

Parameter list | C00597

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00597

C00598

C00599

C00600

Parameter | Name:

C00597 | Resp. to motor phase failure

Data type: UNSIGNED_32

Index: 23978

d

= 5DAA

h

Response to activation of motor phase failure monitoring
Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00598 | Resp. to open circuit AIN1

Data type: UNSIGNED_32

Index: 23977

d

= 5DA9

h

Response if with master current at AIN1 and "LifeZero" mode (±4...±20mA) the current is in the non-permitted range

(-4 ... +4 mA).
Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00599 | Motor phase failure threshold

Data type: INTEGER_32

Index: 23976

d

= 5DA8

h

Current value for activating the

Motor phase failure monitoring

• In [%] relating to the maximum device current (display in

C00789

).

• The response to be triggered by the monitoring can be selected in

C00597

.

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

%

100.0 5.0 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00600 | Resp. to DC bus overvoltage

Data type: UNSIGNED_32

Index: 23975

d

= 5DA7

h

Response to DC bus overvoltage

Braking operation

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1