C00980 | vfc: override point of field weakening, C00985 | slvc: field current controller gain, C00986 | slvc: cross current controller gain – Lenze 9400 User Manual

Page 829: C00987 | slvc: gain - torque controller, C00988 | slvc: reset time - torque contr, C00985, C00986, C00987, C00988, Reset time

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

829

14

Parameter reference

14.2

Parameter list | C00980

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00980

C00985

C00986

C00987

C00988

Parameter | Name:

C00980 | VFC: Override point of field weakening

Data type: INTEGER_32

Index: 23595

d

= 5C2B

h

From software version V8.0

Offset of the override point of field weakening

• In the VFCplus operating mode the pull-out protection function or the maximally permissible current in the field

weakening range can be adapted.

Setting range

(min. value | unit | max. value)

Lenze setting

-500

Hz

500 0 Hz

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00985 | SLVC: Field current controller gain

Data type: UNSIGNED_32

Index: 23590

d

= 5C26

h

From software version V3.0

Sensorless vector control

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

21474836.47 0.00

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00986 | SLVC: Cross current controller gain

Data type: UNSIGNED_32

Index: 23589

d

= 5C25

h

From software version V3.0

Sensorless vector control

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

21474836.47 0.00

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00987 | SLVC: Gain - torque controller

Data type: UNSIGNED_32

Index: 23588

d

= 5C24

h

From software version V3.0

Sensorless vector control

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Hz/A

1000.0000 0.5000 Hz/A

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C00988 | SLVC: Reset time - torque contr.

Data type: UNSIGNED_32

Index: 23587

d

= 5C23

h

From software version V3.0

Sensorless vector control

Setting range

(min. value | unit | max. value)

Lenze setting

0.01

ms

2000.00 10.00 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100