C02609 | brake control: dig. signals, C02610 | deceleration time for stop, C02611 | s-ramp time for stop – Lenze 9400 User Manual

Page 868: C02612 | ref. for decel. time of stop, C02611, C02610, C02612, Refers to a speed variation fr, C02609/1, C02609/2

Advertising
background image

14

Parameter reference

14.2

Parameter list | C02609

868

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02609

C02610

C02611

C02612

Parameter | Name:

C02609 | Brake control: Dig. signals

Data type: UNSIGNED_32

Index: 21966

d

= 55CE

h

Display of the digital signals of the basic function "

brake control

".

Selection list

(read only)

0 FALSE
1 TRUE

Subcodes

Info

C02609/1

BRK_bReleaseBrake

C02609/2

BRK_bStartingTorque2

C02609/3

BRK_bBrakeApplied

C02609/4

BRK_bBrakeTest

C02609/5

BRK_bBrakeGrindIn

C02609/6

BRK_bReleaseBrakeOut

C02609/7

BRK_bBrakeReleased

C02609/8

BRK_bError

C02609/9

BRK_bCInhActive

C02609/10

BRK_bDisableStop

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02610 | Deceleration time for stop

Data type: UNSIGNED_32

Index: 21965

d

= 55CD

h

Basic function "

Stop

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

1000.000 1.000 s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C02611 | S-ramp time for stop

Data type: UNSIGNED_32

Index: 21964

d

= 55CC

h

Basic function "

Stop

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

10.000 0.100 s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C02612 | Ref. for decel. time of stop

Data type: UNSIGNED_32

Index: 21963

d

= 55CB

h

Basic function "

Stop

"

Selection list

(Lenze setting printed in bold)

0 Motor reference speed (C00011)
1 Current speed

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1