Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02621

C02622

C02623

C02624

C02625

Parameter | Name:

C02621 | Manual jog: Speed 2

Data type: INTEGER_32

Index: 21954

d

= 55C2

h

Basic function "

Manual jog

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s

214748.3647 720.0000 Unit/s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02622 | Manual jog: Acceleration

Data type: INTEGER_32

Index: 21953

d

= 55C1

h

Basic function "

Manual jog

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s²

214748.3647 360.0000 Unit/s²

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02623 | Manual jog: Deceleration

Data type: INTEGER_32

Index: 21952

d

= 55C0

h

Basic function "

Manual jog

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s²

214748.3647 1440.0000 Unit/s²

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02624 | Manual jog: S-ramp time

Data type: UNSIGNED_32

Index: 21951

d

= 55BF

h

Basic function "

Manual jog

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

10.000 0.100 s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C02625 | Manual jog: Step size

Data type: INTEGER_32

Index: 21950

d

= 55BE

h

From software version V5.0

Step distance for "

Manual jog with step limitation

" mode.

Basic function "

Manual jog

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit

214748.3647 360.0000 Unit

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000