2 manual jog with step limitation, Manual jog with step limitation ( 403), 11 basic drive functions – Lenze 9400 User Manual

Page 403

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

403

11

Basic drive functions

11.4

Manual jog

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.4.3.2

Manual jog with step limitation

This function extension is available from software version V5.0 onwards!

This mode can be activated via the control input MAN_bStepMode.
In the "Manual jog with step limitation" mode the drive traverses by the "step distance"

parameterised in

C02625

if a direction is requested via the control inputs MAN_bJogPositive/

MAN_bJogNegative. After traversing this distance, the drive stops.

• A new positive edge for the routing request causes a restart of the function or a reset of the

distance counter, even if the drive is not at standstill yet.

• If the routing request is reset before the distance is reached, the drive stops immediately (with

the deceleration set).

Note!

The two modes "Manual jog with step limitation" and "Manual jog with intermediate

stop" cannot be active at the same time.
If there is a simultaneous request via the control inputs MAN_bStepMode and

MAN_bIntermediateStopMode, only the "Manual jog with intermediate stop" mode is

active.

Manual jog with intermediate stop

( 404)

Advertising