C02645 | homing: acceleration 1, C02646 | homing: speed 2, C02647 | homing: acceleration 2 – Lenze 9400 User Manual

Page 875: C02648 | homing: s-ramp time, C02649 | homing: torque limit, C02645, C02646, C02647, C02648, C02649

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

875

14

Parameter reference

14.2

Parameter list | C02645

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02645

C02646

C02647

C02648

C02649

Parameter | Name:

C02645 | Homing: Acceleration 1

Data type: INTEGER_32

Index: 21930

d

= 55AA

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s²

214748.3647 720.0000 Unit/s²

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02646 | Homing: Speed 2

Data type: INTEGER_32

Index: 21929

d

= 55A9

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s

214748.3647 0.0000 Unit/s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02647 | Homing: Acceleration 2

Data type: INTEGER_32

Index: 21928

d

= 55A8

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s²

214748.3647 360.0000 Unit/s²

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02648 | Homing: S-ramp time

Data type: INTEGER_32

Index: 21927

d

= 55A7

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

10000 100 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02649 | Homing: Torque limit

Data type: INTEGER_32

Index: 21926

d

= 55A6

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

200.00 10.00 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100