Parameter list | C02650

876

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02650

C02651

C02652

C02653

C02655

Parameter | Name:

C02650 | Homing: Blocking time

Data type: UNSIGNED_32

Index: 21925

d

= 55A5

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

120.000 1.000 s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C02651 | Homing: TP configuration

Data type: UNSIGNED_32

Index: 21924

d

= 55A4

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0

4294967295 16

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02652 | Ref. pos. after mains switching

Data type: UNSIGNED_32

Index: 21923

d

= 55A3

h

Basic function "

Homing

"

Selection list

(Lenze setting printed in bold)

0 Delete
1 Retain

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02653 | Max. rot. ang. aft. mns. swtch.

Data type: INTEGER_32

Index: 21922

d

= 55A2

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0

°

1000000 180 °

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02655 | HM_dnSpeedOverride_n

Data type: INTEGER_32

Index: 21920

d

= 55A0

h

From software version V5.0

Display of the speed override for the basic function "

Homing

".

Display range

(min. value | unit | max. value)

-200.00

%

200.00

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100