C02701 | software limit positions, C02702 | limitations effective, C02703 | max. speed – Lenze 9400 User Manual

Page 884: C02704 | max. speed [rpm, C02705 | max. acceleration, C02701/1, C02701/2, C02703, C02705, S set in

Advertising
background image

14

Parameter reference

14.2

Parameter list | C02701

884

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02701

C02702

C02703

C02704

C02705

Parameter | Name:

C02701 | Software limit positions

Data type: INTEGER_32

Index: 21874

d

= 5572

h

Basic function "

Limiter

"

Setting range

(min. value | unit | max. value)

-214748.3647

Unit

214748.3647

Subcodes

Lenze setting

Info

C02701/1

0.0000 Unit

Positive software limit position

C02701/2

0.0000 Unit

Negative software limit position

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02702 | Limitations effective

Data type: UNSIGNED_32

Index: 21873

d

= 5571

h

Basic function "

Limiter

"

Selection list

(Lenze setting printed in bold)

0 Deactivated
1 Activated

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02703 | Max. speed

Data type: INTEGER_32

Index: 21872

d

= 5570

h

Basic function "

Limiter

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s

214748.3647 3600.0000 Unit/s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02704 | Max. speed [rpm]

Data type: INTEGER_32

Index: 21871

d

= 556F

h

Basic function "

Limiter

"

Display range

(min. value | unit | max. value)

0.0

rpm

214748364.7

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C02705 | Max. acceleration

Data type: INTEGER_32

Index: 21870

d

= 556E

h

Basic function "

Limiter

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s²

214748.3647 3600.0000 Unit/s²

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000